TM 9-2320-392-10-2
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
105. ENGINE FAN RUNS
2. Allow engine to idle until 120
CONSTANTLY -
psi is registered on FRONT
Continued
BRAKE AIR and REAR BRAKE
AIR pressure gages.
3. Shut down engine (WP 0018
00).
4. If FRONT BRAKE AIR or REAR
BRAKE AIR pressure gage does
not register 120 psi, perform
Air System Troubleshooting
Air System Loses Pressure
During Operation/Slow Air
Pressure Buildup).
3. Check to see if
If engine fan runs constantly,
engine fan runs
notify Field Maintenance.
constantly (WP 0004
00).
0080 00-101