TM 9-2320-392-10-2
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
101. 15K SELF-
1. Check to see if 15K
If 15K SRW does not reel in,
RECOVERY WINCH
SRW reels in (WP
perform Malfunction 99 (15K
(SRW) DOES NOT
0065 00).
Self-Recovery Winch (SRW)
PAY OUT
Does Not Reel In Or Pay Out).
2. Check to see if 15K
If 15K SRW does not pay out,
SRW pays out (WP
notify Field Maintenance.
0065 00).
NOTE
Perform PTO Troubleshooting (WP 0083 00, Malfunction 1, Power Take-Off
(PTO) Does Not Engage) before starting here.
102. POWER TAKE-OFF
1. Check circuit
(PTO) DOES NOT
breakers CB43 in PCB
ENGAGE
to see if it is tripped.
2. If circuit breaker is tripped,
push in to reset.
3. Position master power switch
to on (WP 0004 00).
0080 00-96