TM 9-2320-366-20-5
(2) Install 90-degree fitting (4) in lower cover (5).
CAUTION
When installing a new air dryer, it is
necessary to change the orientation of the
retaining bands. Failure to comply may result
in damage to equipment.
NOTE
Perform steps (3) through (5) if installing a
new air dryer.
(3) Loosen two nuts (6) on retaining bands (7).
NOTE
Position retaining bands on air dryer as noted
in removal.
(4) Rotate two retaining bands (7) 90-degrees clockwise as
viewed from top of air dryer (8).
(5) Tighten two nuts (6) on retaining bands (7).
Change 1
23-47