TM 9-2320-366-20-5
20-57. 200 AMP TERMINAL BLOCK TO POWER DISTRIBUTION PANEL (PDP) 24 VDC
CABLE REPLACEMENT (CONT)
b. Installation.
NOTE
Install plastic cable ties as required.
(1) Route 200 amp terminal block to PDP 24 vdc cable (1)
through bottom of cab (2).
(2) Position 200 amp terminal block to PDP 24 vdc cable (1)
in clamp (3).
(3) Position clamps (3 and 4) on frame rail (5) with washer
(6), screw (7), washer (8), and self-locking nut (9).
(4) Tighten self-locking nut (9) to 97-120 lb-in. (11-14 Nm).
(5) Position 200 amp terminal block to PDP 24 vdc cable (1)
in clamp (10)
(6) Position clamp (10) on frame rail (5) with screw (11) and
self-locking nut (12).
(7) Tighten self-locking nut (12) to 97-120 lb-in. (11-14 Nm).
20-316