TM 9-2320-366-20-4
11-31. AIR COMPRESSOR GOVERNOR REPLACEMENT/REPAIR/ADJUSTMENT (CONT)
c. Cleaning/Inspection.
WARNING
Dry cleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use
only in well ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors.
Keep away from heat or flame. Never smoke when using solvent; the flashpoint for Type I dry
cleaning solvent is 100 F (38 C) and for Type II is 130 F (50 C). Failure to comply may result
in serious injury or death to personnel.
If personnel become dizzy while using dry cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes,
immediately flush eyes with water and get immediate medical attention. Failure to comply may
result in injury to personnel.
Wear protective goggles to protect against possible injury from release of high pressure air.
Failure to comply may result in injury to personnel.
NOTE
Replace any part that fails visual inspection.
(1) Clean all metal parts with dry cleaning solvent.
(2) Clean all internal passages with pressurized air.
(3) Inspect all parts for cracks, corrosion, or wear.
d. Assembly.
NOTE
Apply lubricating oil to preformed packings,
piston, governor bore, and pin prior to
assembly.
(1) Install two preformed packings (1) and preformed
packing (2) on piston (3).
(2) Install valve disk (4) and spring (5) in piston (3).
(3) Install pin (6) and spring (7) in piston (3).
(4) Install piston (3) in air compressor governor (8).
11-186.2