TM 9-2320-366-20-4
b. Installation.
(1) Install WTEC III TPSS (1) in instrument panel assembly
(2).
(2) Position two brackets (3) and self-locking nuts (4) on
WTEC III TPSS (1).
(3) Tighten two self-locking nuts (4) to 11-13 lb-in. (1-2
Nm).
(4) Connect connector PX33 (5) to WTEC III TPSS
connector (6).
c. Calibration.
(1) Install instrument panel assembly (para 7-15).
NOTE
steps (1.1) through (4).
(1.1) Position master power switch to on and wait for neutral
(N) indication from WTEC III TPSS (TM 9-2320-366-10-
1).
(2) Position master power switch to off (TM 9-2320-366-10-
1).
(3) Perform steps (1) and (2) four more times.
(4) Position master power switch to on (TM 9-2320-366-10-
1).
(5) Start engine (TM 9-2320-366-10-1).
(6) Check volts gage for charge indication (TM 9-2320-366-
10-1).
Change 1