TM 9-2320-366-20-4
7-143. M1084/M1086 JUNCTION BOX MODIFICATION (CONT)
(56) Route black wire (53) to terminal block (54).
(57) Cut black wire (53) to length.
(58) Install connector (55) on black wire (53).
(59) Connect black wire (53) on terminal block (54) position
25 with screw (56).
(60) Remove loose dirt and dust from inside of cover (3).
(61) Install new decal (57) on inside of cover (3).
(62) Close cover (3) on junction box (2).
(63) Tighten four screws (1) on junction box (2).
b. Follow-On Maintenance.
(1) Connect batteries (para 7-57).
(2) Operate MHC and check shutdown relay for proper
operation (TM 9-2320-366-10-1).
End of Task.
7-714