TM 9-2320-366-20-4
NOTE
Perform steps (20) through (39) on lockout
Relay socket wires must be trimmed to length
according to nearest routing in junction box.
(20) Route green wire (28) to ground strip (5).
(21) Cut green wire (28) to length.
(22) Install quick disconnect terminal (29) on green wire (28).
(23) Connect green wire (28) on ground strip (5) position 20.
(24) Route white wire (30) to terminal block (7).
(25) Cut white wire (30) to length.
(26) Install connector (31) on white wire (30).
(27) Connect white wire (30) on terminal block (7) position 8
with screw (32).
(28) Route red wire (33) to terminal block (7).
(29) Cut red wire (33) to length.
(30) Install connector (34) on red wire (33).
(31) Connect red wire (33) on terminal block (7) position 10
with screw (35).
Change 1