TM 9-2320-366-20-4
NOTE
Perform steps (20) and (21) on vehicles
(20) Install terminal lug TL36 (32) on reverse polarity relay 24
VDC BAT terminal (33) with lockwasher (34) and nut
(35).
(21) Position terminal cover (36) on terminal lug TL36 (32).
(22) Install terminal lug TL38 (37) on lower shunt terminal
(38) with washer (39) and screw (40).
(23) Install terminal lug TL51 (41) on upper shunt terminal
(42) with washer (43) and screw (44).
(24) Install connector J106 (45) on chemical detector
mounting bracket (46) with dust cap lanyard (47) and nut
(48).
(25) Install dust cap (49) on connector J106 (45).
7-653