(15) Remove screw (26) from PDP (27).
(16) Position four terminal lugs (28) and terminal lug TL42
(29) on PDP (27) with lockwasher (30) and screw (26).
(17) Tighten screw (26) to 35-45 lb-in. (4-5 Nm).
(18) Install PDP (27) on dashboard (31) with three screws
(32).
(19) Install three washers (33) and screws (34) in PDP (27).
c. Follow-On Maintenance.
(1) Install bottom radiator fan shroud (para 6-4).
(2) Raise spare tire (TM 9-2320-366-10-2).
(4) Connect batteries (para 7-57).
(5) Start engine (TM 9-2320-366-10-1).
(6) Check VOLTS gage for charge indication (TM 9-2320-
366-10-1).
(7) Shut down engine (TM 9-2320-366-10-1).
End of Task.