b. Installation
(1) Position right jack cylinder proximity sensor cable (1)
through clamp (2).
(2) Position right jack cylinder proximity sensor cable (1)
through compression nut (3), washer (4) and connector
(5).
(3) Install washer (4) and compression nut (3) on connector
(5).
(4) Tighten nut (6) on clamp (2).
(5) Install quick disconnect terminal (7) on red wire (8).
(6) Install terminal lug (9) on white wire (10).
(7) Install terminal lug (11) on black wire (12).
(8) Install quick disconnect terminal (7) on ground strip (13)
position 14.
(9) Install terminal lug (9) on terminal block (14) position 6
with screw (15).
(10) Install terminal lug (11) on terminal block (14) position 11
with screw (15).
(11) Apply varnish to quick disconnect terminal (7) and
terminal lugs (9 and 11).