TM 9-2320-366-20-4
NOTE
Tag wires and connection points prior to
disconnecting.
(6) Remove ten screws (9) from terminal block (10) positions
17 through 26.
(7) Remove two screws (11) from terminal block (12)
positions 9 and 14.
(8) Disconnect quick disconnect terminal (13) from ground
strip (14) position 12.
(9) Remove four nuts (15), lockwashers (16), screws (17),
and remote control cable (18) from junction box (7).
Discard lockwashers.
b. Installation.
(1) Install remote control cable (1) in junction box (2) with
7-475