TM 9-2320-272-24-2
Loosen clamps (2) and (6) and remove hoses (1) and (5) from fittings (3) and (7).
46.
Disconnect oil cooler return hose (23) from temperature transmitter adapter (24).
47.
Disconnect transmission supply hose (25) from lubrication valve adapter (26).
48.
Remove nut (29), screw (34), clamp (33), and hose (32) from bracket (30).
49.
Remove clamps (53) and (35) and hose (32) from surge tank fitting (27) and tube (48).
50.
NOTE
Perform steps 51 and 52 for internal bypass systems.
Remove two clamps (42) and hose (43) from fitting (52) and thermostat canister (41).
51.
Remove two clamps (44), thermostat canister (41), and hose (45) from tube (38).
52.
NOTE
Perform step 53 for external bypass systems.
Remove two clamps (42) and hose (43) from fitting (54) and tube (38).
53.
Remove two clamps (36), hump hose (37), two clamps (39), hump hose (40), and tube (38) from
54.
outlet tube (31) and transmission oil cooler (51).
Remove two clamps (50). elbow (49), two clamps (47), elbow (46), and tube (48) from outlet port (28)
55.
and transmission oil cooler (51).
4-73