TM 9-2320-260-20
13-61. TRANSMISSION PTO LINKAGE MAINTENANCE (Contd)
WARNING
Drycleaning solvent is flammable and will not be used near open
flame. Use only in well-ventilated places. Failure to do so may
result in injury to personnel.
q Compressed air source will not exceed 30 psi (207 kpa). When
cleaning with compressed air, eyeshields must be worn. Failure
to wear eyeshields may result in injury to personnel.
1. Clean all parts using drycleaning solvent. Dry parts using compressed air.
2. Inspect shaft (17) for twists, bends, and cracks. Replace if damaged.
3. Inspect link rod (9) and connecting rod (24) for twists, bends, and cracks. Replace rods (9) and (24)
if damaged.
4. Inspect control lever (6) and lever (19) for cracks, breaka, and twists. Replace levers (6) and (19)
if damaged.
1. Position jamnut (26) and clevis end (22) on connecting rod (24).
2. Pull quick-release pin (21) out and install connecting rod (24) on power takeoff lever (28),
3. Install two brackets (15) and new woodruff keys (16) on shaft (17).
4. Install lever (19) on shaft (17) with screw (20) and new locknut (18).
5. Install lever (11) on shaft (17) with screw (13) and new locknut (12).
6. Install stop (4) on bracket (1) with screw (3) and new locknut (5).
1. Install power takeoff lever (28) on power takeoff (33) with screw (32) and new locknut (29).
2. Install power takeoff lever (28) on power takeoff (33) with new lockwasher (31) and screw (30).
3. Install shaft (17) and two brackets (15) on crossmember (35) with four screws (14) and new
locknuts (27).
4. Install connecting rod (24) on lever (19) with clevis pin (23) and new cotter pin (25).
5. Install bracket (1), spacer (7), and control lever (6) on shaft (34) and crossmember (36) with two
screws (37) and new locknuts (2).
6. Install link rod (9) on control lever (6) and lever ( 11) with two clevis pins (10) and new cotter
pins (8).
13-136