TM 9-2320-260-20
I
13-52. VAN LIFTGATE CONTROL VALVE REPLACEMENT (Contd)
4. Install nipple (22), flow control valve (23), and two connectors (14) on tees (10).
5. Install control valve (3) on main frame mount (4) with three new lockwashers (2), screws (1),
and nuts (9).
6. Connect hydraulic hoses (7) and (5) to tee (8) and adapter (6).
7. Connect hydraulic hoses (11) and (12) to two tees (10).
8. Connect hydraulic hoses (15) and (16) to two connectors (14).
9. Connect hydraulic hoses (13) and (17) to control valve (3).
FOLLOW-ON TASKS: q Fill hydraulic system (LO 9-2320-260-12).
q Operate liftgate (TM 9-2320-260-10) and check for leaks.
13-121