LO 9-2350-247-12
LUBRICATION ORDER
(Supersedes LO 9-2350-247-12, March 1982)
8 JULY 1994
KEY
REFILL
EXPECTED TEMPERATURES*
CAPACITY
INTERVALS
+5F to +120F +40F to -60F
(APPROX)
OE/HDO (MIL-L-2104D)
M - Monthly
0.75 Pt.
OEA
OE/HDO-15/40
ENGINE
S - 150 Hours,
GREASE, AUTOMOTIVE
As
GAA (MIL-G-10924)
1,500 Miles
Required
All Temperatures
AND ARTlLLERY
or Semi-annually
For Arctic Operation Refer to FM 9-207
NOTES
1. PULLEY SUPPORT ARM. Every 1,500 miles or
NOTE
semi-annually, lubricate with grease (GM). Use grease
Drain oil only when hot after operation.
gun with flexible adapter on fitting.
3. FAN GEAR BOX OIL DRAIN. Drain gear box oil
2. FAN GEAR BOX. Monthly, check fan gear box oil
every 1,500 miles or semi-annually.
level. Oil should be between ADD and FULL marks.
Maintain oil level with OE/HDO or OEA as required by
Temperature Key Chart.
Card 19 of 40