TM 9-2320-392-10-2
DUMP BODY HYDRAULIC SYSTEM
0096 00
TROUBLESHOOTING - Continued
DUMP BODY HYDRAULIC SYSTEM - Continued
Table 1. Dump Body Hydraulic System
Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
DUMP BODY DOES
6.
If PTO does not engage,
NOT LOWER -
perform Hydraulic System
Continued
Malfunction 1, Loss of
Hydraulic Pressure [Single
Stage Pump]).
3.
Check to see if
If dump body does not lower,
dump body lowers
notify Field Maintenance.
(WP 0031 00).
NOTE
Hydraulic reservoir is considered full when oil level gage reads above 3/4
mark.
3.
DUMP BODY
1.
Check hydraulic oil
If oil level is low, add
DRIFTS DOWN
level gage to
FROM RAISED
determine
Table 3, Item 8).
POSITION
hydraulic oil level
Table 3, Item 8).
0096 00-4