TM 9-2320-392-10-2
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
31. DUMP BODY UP
4. Is circuit breaker
INDICATOR DOES
CB21 tripped?
NOT ILLUMINATE -
Continued
2. If circuit breaker CB21 is
tripped, push button to reset.
3. Position master power switch
to on (WP 0004 00).
4. Check circuit breaker CB21 to
see if it is tripped again.
5. Position master power switch
to off (WP 0004 00).
7. If circuit breaker CB21 is
tripped, notify Field
Maintenance.
8. If circuit breaker CB21 is not
tripped, go to test 6 of this
malfunction.
0080 00-44