TM 9-2320-392-10-1
EMERGENCY PROCEDURES - Continued
0066 00
MATERIAL HANDLING CRANE (MHC) OPERATION AFTER ELECTRICAL FAILURE
(M1084A1/M1086A1 AND M1089A1)
NOTE
Emergency MHC operation is the same for M1084A1/M1086A1 and M1089A1.
M1084A1/M1086A1 MHC shown.
1.
Remove retaining pin (12) from pump handle (13).
2.
Remove pump handle (13) from stowed position.
3.
Install pump handle (13) in manual hydraulic pump (14).
4.
Place HOIST lever (15) in DOWN position and operate manual hydraulic pump (14) to
lower load as required.
0066 00-8