TM 9-2320-366-20-4
b. Installation.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(1) Apply sealing compound to threads of 45-degree fitting
(1), 90-degree fitting (2), and fitting (3).
(2) Install 45-degree fitting (1) in quick release valve (4).
(3) Install 90-degree fitting (2) in quick release valve (4).
(4) Install fitting (3) in quick release valve (4).
(5) Position quick release valve (4) on bracket (5) with two
washers (6), screws (7), washers (8), and self-locking
nuts (9).
(6) Tighten two self-locking nuts (9) to 14-18 lb-ft (20-24
Nm).
11-95