TM 9-2320-366-20-4
(2) Install quick disconnect terminal (6) on ground strip (7)
position 1.
(3) Install 12 terminal lugs (8) on terminal block (9) positions
7 through 18 with 12 screws (10).
(4) Apply varnish to quick disconnect terminal (6) and 12
terminal lugs (8).
(5) Close cover (11) on junction box (2).
(6) Tighten four screws (12) on junction box (2).
(7) Install connector (13) in mounting bracket (14) with
lockwasher (15) and nut (16).
(8) Install cap (17) on connector (13).
c. Follow-On Maintenance.
(1) Connect batteries (para 7-57).
(2) Operate MHC and check right side remote operation (TM
9-2320-366-10-2).
End of Task.
7-587