TM 9-2320-272-24-2
4-12. CYLINDER HEAD REPLACEMENT (Contd)
WARNING
Compressed air source will not exceed 30 psi (207 kPa).When
l
cleaning with compressed air, eyeshields must be worn. Failure
to wear eyeshields may result in injury to personnel.
l Drycleaning solvent is flammable and will not be used near
open flame. Use only in well-ventilated places and keep fire
extinguisher nearby. Failure to do so may result in injury
to personnel.
4.
Place cylinder head (4) in cylinder head holding fixture, steam-clean cylinder head (4), and dry with
compressed air.
4-121