TM 9-2320-272-24-1
3-203. SECONDARY AIR RESERVOIR (SUPPLY TANK) REPLACEMENT (Contd)
b. Installation
NOTE
If installing new reservoir, use old reservoir fittings.
l
Wrap all male pipe threads with antiseize tape before
l
installation.
Place secondary reservoir (5) in soft-jawed vise.
1.
Install fitting (12), adapter (16), and elbow (13) on secondary reservoir (5).
2.
Install adapters (9) and (10) on secondary reservoir (5).
3.
4.
Install check valve (6) and elbow (8) on secondary reservoir (5).
Install fitting (4), adapter (3), and secondary low-air pressure switch (2) on secondary reservoir (5).
5.
Remove secondary reservoir (5) from soft-jawed vise.
6.
NOTE
Assistant will support reservoir during step 7.
Install secondary reservoir (5) on two hangers (17) with support clamps (19), four screws (18), and
7.
new locknuts (20).
Connect two wires (1) to secondary low-air pressure switch (2).
8.
9.
Connect supply line (15) to adapter (16).
10.
Connect supply line (14) to elbow (13).
11.
Connect drainvalve line (11) to adapter (10).
Connect wet reservoir supply line (7) to elbow (8).
12.
3-568