TM 9-2320-26044-2
16-22. CRANE GONDOLA MAINTENANCE (M816) (Contd)
b. Disassembly
NOTE
Mark brackets for installation.
1. Remove twelve locknuts (2), screws (6), and brackets (3) and (5) from gondola body (1). Discard
locknuts (2).
2. Remove six screw-assembled Iockwashers (10) and cover (9) from gondola body (1). Discard screw-
assembled Iockwashers (10).
3. Remove six screws (7) and cover (8) from gondola body (1).
4. Remove three seals (16) from gondola body (1). Discard seals (16).
5. Remove anti-chafing channel (15) from gondola body (1).
6. Remove two screws (13) and oil can bracket (14) from gondola body (1).
NOTE
Perform step 7 if cover and data plates were installed after control
valve was removed.
7. Remove four screws (11) and cover (12) from gondola body (1).
c. Cleaning, Inspection, and Repair
1. For general cleaning instructions, refer to para. 2-8.
2. For general inspection instructions, refer to para. 2-9.
a. Inspect seals (16) and anti-chafing channel (15) for tears, chafing, cracks, and missing sections.
NOTE
Cover and data plates were removed in equipment condition step,
but are included for inspection and repair of gondola.
b. Inspect cover (12) and warning, caution, and data plates for legibility, and secure for anchorage.
3. Repair damaged and worn parts (para. 2-10). Replace all worn or damaged parts that are
unrepairable.
4. Inspect wooden hose supports (4) on bracket (3) and in gondola body (1). Repair or replace wooden
hose supports (4) if damaged.
16-132