TM 9-2320-260-34-2
15-86. CONVERTER JUNCTION BOX REPLACEMENT (Contd)
1.
Place nut (11) on conduit (2) and route harnesses (1) and (4), and wires (3) through holes in junction
box (10).
2.
Route harness (4) through conduit (5).
Position junction box (10) on conduits (2) and (5). Install adapter (8) on junction box (10) and
3.
conduit (5) with nut (7) and coupling (9).
Install nut (11) on junction box (10).
4.
Install connectors (12) and (14) on cover (20) with eight screws (13) and new locknuts (19).
5.
6.
Solder four wires (18) and three wires (3) on connectors (14) and (12).
NOTE
Apply sealing compound to cover.
Install cover (20) on junction box (10) with eight screws (15).
7.
Connect wiring harnesses (17) and (16) to connectors (12) and (14).
8.
Position new gasket (24) and cover (23) on outlet box (25) and solder three wires (26) to
9.
connector (27). Remove safety wire from wires (26).
Install new gasket (24) and cover (23) on outlet box (25) with four screws (22).
10.
11.
Connect auxiliary pump wiring harness (21) to connector (27).
15-324