TM 9-2320-260-34-2
15-82. LOAD CENTER MAINTENANCE (Contd)
16.
Remove setscrew (7) and wire (6) from neutral bar (2).
Remove three screws (4) and wires (5) from 30-amp circuit breaker (3).
17.
18.
Remove 10kW electric heater wiring harness (8) from load center (1).
Remove setscrew (13) and wire (14) from neutral bar (2).
19.
Remove screw (11) and wire (12) from 20-amp circuit breaker (10).
20.
21.
Remove heater wiring harness (9) from load center (1).
NOTE
Perform steps 22 through 27 for M820 and M820A2 vehicles.
22.
Disconnect auxiliary pump wiring harness (15) from connector (16).
23.
Remove four screws (17), cover (18), and gasket (19) from outlet box (20). Discard gasket (19).
Desolder three wires (21) from connector (16).
24.
25.
Disconnect converter wiring harnesses (26) and (27) from connectors (29) and (25).
26.
Remove eight screws (28) and cover (24) from junction box (22).
27.
Desolder three wires (23) and four wires (30) from connectors (25) and (29).