TM 9-2320-260-34-2
15-35. INTERIOR SIDE PANELS AND LATCHES REPLACEMENT (Contd)
NOTE
q Left and right latches are installed the same. This procedure
covers the right side.
q Insulate areas of dissimilar metal-to-metal contact with zinc
chromate primer.
q Seal area between exterior joints with sealing compound.
q Apply adhesive to rubber and metal surfaces.
1.
Install new rubber bumper (2) on side panel frame (4) with screw (1).
Install retainer (30) on side panel frame (4) with two screws (31).
2.
Install horizontal bar (25) and flush bolt (3) in side panel frame (4).
3.
Install clevis (24) on horizontal bar (25).
4.
Install clevis (26) on flush bolt (3).
5.
Install latch (22) on side panel frame (4) with four new lockwashers (10) and nuts (11).
6.
Install clevises (24) and (26) on latch (22) with two pins (19) and new cotter pins (23).
7.
Install new O-ring (6), shank (5), new gasket (9), and plate (8) on latch (22) with two screws (7).
8.
Install washer (21) and nut (20) on shank (5) and latch (22).
9.
Install left latch (22) (steps 2 through 9).
10.
NOTE
q Insulate entire structure with fibrous glass felt insulation,
q Assistant will help with step 11.
Position moldings (27), (28), (29), (17), (18), and (12) on panel (16).
11.
Install panel (16) on side panel frame (4) with thirty-three screws (13).
12.
13.
Install plate (14) on panel (16) with eight screws (15).
15-126