TM 9-2320-260-20
Table 2-4. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
35. HORN DOES NOT OPERATE
NOTE
Electrical troubleshooting of the electric horn and air horn is
the same.
Test 1. Test input voltage to horn circuit breaker.
Step 1. Turn battery switch to ON position and ignition switch to RUN position.
Step 2. Remove lead 25 from horn circuit breaker.
Step 3. Set multimeter to a voltage range that will measure 24 volts.
Step 4. Touch negative lead of multimeter to frame ground.
Step 5. Touch positive lead of multimeter to horn circuit breaker contact.
a. Replace horn circuit breaker if voltage is not present (para. 4-20).
b. If voltage is present, go to test 2.
2-164