TM 9-2320-260-20
Table 2-1. Unit Level Preventive Maintenance Checks and Services (Contd).
NOT FULLY
ITEM TO
PROCEDURE
ITEM
INTERVAL
MISSION
CHECK/
CAPABLE IF
SERVICE
13
a. Inspect alternator (6) for secure mounting.
Semi-
annual
and
Alternator is
b. If loose, tighten two screws (1) on alternator
alternator adjusting link (2) 25-31 lb-ft (34-42 N q m).
loose or screws and
wiring
nuts missing.
c. Tighten two nuts (5) and screws (3) on each side of
alternator mounting bracket (4) 50-55 lb-ft (68-75 N q m).
d. Inspect alternator wiring for burned or frayed wires
Wiring insulation
is missing, frayed,
and loose or broken terminal connections. Tighten if
split, or poor
loose. Replace or repair wiring if burned, frayed, or
connections are
evident.
.
Preheater Inspect tubing (8) and wiring (7) for loose connections
14
Semi-
annual
glow plug
2-8