TM 11-7440-293-14
4-7. INSTALLING KEY GENERATOR RACK TO ELECTRONIC EQUIPMENT TABLE.
This task covers:
Installation
INITIAL SETUP
Tools
Personnel Required
1/2-inch box wrench (2 required)
One mechanic
Materials/Parts
Equipment Condition
Mounting holes predrilled.
5/16-24 x 2 1/4 inch long hex head
screw (4 required)
5/16-inch flat washer (8 required)
5/16-inch nut, self-locking (4 required)
Key generator rack
ACTION
REMARKS
ITEM
LOCATION
Key generator
1.
Electronic equip-
rack (1) and
ment table and aline holes.
ment table, road-
side
electronic
equipment
table (2)
2.
Key generator and
Screw (3), flat
Install, handtighten.
There are four screws. Step 2 is
electronic equip-
washers (4) and
nut (5)
typical for all four screws.
ment table
3.
Do step 2 again.
Screw holes (6)
Using two 1/2-inch box wrenches, tighten.
Screw (3) and
4.
There are four screws. Step 4 is
nut (5)
typical for all four screws.
Do step 4 again.
Screws (3) and
5.
nuts (5)
4-8