TM 9-2320-392-10-2
M1083A1 SERIES PREVENTIVE MAINTENANCE
0103 00
CHECKS AND SERVICES (PMCS) - Continued
Table 21. Preventive Maintenance Checks and Services (PMCS) - Monthly -
Model M1089A1 - Continued.
ITEM
INTERVAL
MAN-
ITEM
CREWMEMBER
EQUIPMENT
NO.
HOUR
TO BE
PROCEDURE
NOT READY/
CHECKED
AVAILABLE
OR
IF:
SERVICED
3
Monthly
Material
3. Check security of
Handling
electrical connectors
Crane
on overload shutdown
(MHC) -
box (5).
Continued
4. Inspect electrical
Wiring is
frayed,
fraying and excessive
cracked, or
wear.
excessively
worn.
4
Monthly
0.1
Oil Can
Lubricate all oil can
Points
points with OE/HDO
specified for ambient
temperature. The
operator/crew is
responsible for
lubricating the
following points:
1. Tool box latches
and hinges
0103 00-227