TM 9-2320-392-10-2
M1083A1 SERIES PREVENTIVE MAINTENANCE
0103 00
CHECKS AND SERVICES (PMCS) - Continued
Table 17. Preventive Maintenance Checks and Services (PMCS) - Before -
Model M1089A1 - Continued.
ITEM
INTERVAL
MAN-
ITEM
CREWMEMBER
EQUIPMENT
NO.
HOUR
TO BE
PROCEDURE
NOT READY/
CHECKED
AVAILABLE
OR
IF:
SERVICED
9
Before
Hydraulic Oil
CAUTION
Oil level must not be above FULL line or below FILL line on hydraulic tank.
Failure to comply may result in damage to equipment.
1. Check hydraulic oil
Oil level is
level at sight gage
above FULL
(27)
line.
2. Remove cap (28)
from hydraulic tank
(29) and fill hydraulic
tank to proper level.
3. Install cap (28) on
hydraulic tank (29).
0103 00-192