TM 9-2320-392-10-2
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
164. AUDIBLE ALARM,
1. Check circuit breaker
RADIO, STARTER
CB77 in PCB to see if
PUSHBUTTON,
it is tripped.
AND ELECTRICAL
GAGES DO NOT
OPERATE
2. If circuit breaker is tripped,
push in to reset.
3. Position master power switch
to on (WP 0004 00).
4. Check circuit breaker to see if
it is tripped again. If circuit
breaker is tripped again, notify
Field Maintenance.
5. Position master power switch
to off (WP 0004 00).
2. Check to see if
If audible alarm, radio, starter
audible alarm, radio,
pushbutton, and electrical
starter pushbutton,
gages do not operate, notify
and electrical gages
Field Maintenance.
operate (WP 0018
00).
0080 00-134