TM 9-2320-392-10-2
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. 24 VDC CIRCUITS
5. Check to see if circuit breaker
DO NOT OPERATE
CB45 is tripped.
Continued
6. If circuit breaker CB45 is
tripped, push in to reset.
7. Position master power switch
to on (WP 0004 00).
8. If circuit breaker CB45 trips
again, notify Field
Maintenance.
9. Position master power switch
to off (WP 0004 00).
10. If circuit breaker CB45 was not
tripped or does not trip again,
got to test 7 of this
malfunction.
0080 00-12