TM 9-2320-366-20-5
20-58. 200 AMP TERMINAL BLOCK REPLACEMENT (CONT)
(12) Remove eight self-locking nuts (29), washers (30),
screws (31), two terminal blocks (32), and identification
plate (33) from bracket (27). Discard self-locking nuts.
b. Installation.
CAUTION
Both terminal blocks must be positioned
loosely to align correctly on mounting bracket
before tightening hardware.
Failure to
comply may result in damage to equipment.
(1) Position identification plate (1) and two terminal blocks
(2) on bracket (3) with eight screws (4), washers (5), and
self-locking nuts (6).
(2) Tighten eight self-locking nuts (6) to 48 lb-in. (5 Nm).
20-322