TM 9-2320-272-24-4
5-96. 400 HZ SUPPLY WIRING HARNESS REPLACEMENT (Contd)
5.
Disconnect cables (13) and (12) from connectors (14) and (10).
6.
Remove eight screws (11) and electrical connector box cover (15) from electrical connector box (16).
7.
Disconnect four wires (7) from connector (14).
8.
Remove six screws (9) and cover (1) from load center (5).
9.
Remove screw (2) and clamp (3) from harnesses (4) and (8) and load center (5).
10.
Pull wiring harness (8) out of coupling (6) and remove from load center (5) and electrical connector
box (16).
b. Installation
1.
Push wiring harness (8) through coupling (6), electrical connector box (16), and load center (5).
2.
Connect four wires (7) to connector (14).
3.
Install clamp (3) on harnesses (4) and (8) and load center (5) with screw (2).
4.
Install cover (1) on load center (5) with six screws (9).
5.
Apply sealing compound to screws (11) and install electrical connector box cover (15) on electrical
connector box (16) with eight screws (11).
6.
Connect cables (13) and (12) to connectors (10) and (14).
5-592