THIS TASK COVERS:
a. Setting Up Injection Tester
INITIAL SETUP:
APPLICABLE MODELS
TOOLS
M939/A1
SPECIAL TOOLS
REFERENCES (TM)
TM 9-2320-272-24P
a. Setting Up Injection Tester
Rotate counter wheel (2) on injection tester until wheel marks and pointer are aligned.
1.
2.
Open hydraulic valve (3).
CAUTION
Never operate test stand with load cell in position.
Position load cell tester on injection tester and secure by opening air valve (4).
3.
4.
Adjust air regulator (5) by turning knurled knob (7) until load cell tester registers within coded
range markings. Record air gauge (1) pressure reading.
5.
Lock air regulator (5) in place with locknut (6).
6.
Place air valve (4) to center position and remove load cell tester from injection tester.