TM 9-2320-272-24-2
3-445. HYDRAULIC RESERVOIR SHUTOFF MODIFICATION KIT REPLACEMENT (Contd)
Remove adapter assembly (8) and O-ring (10) from check valve (7). Discard O-ring (10).
6.
Remove hose assembly (1), union assembly (5), check valve (2), and nipple (3) from hydraulic oil
7.
reservoir (4).
NOTE
When applying pipe sealant to male threads, leave first two
starter threads clear of sealing compound before installing.
Sealing compound is not necessary on adapter assemblies with
O-rings.
Install nipple (3) on hydraulic oil reservoir (4).
1.
WARNING
Ensure directional arrow on check valve points toward the
hydraulic oil reservoir. Failure to do this may result in injury to
personnel and damage to equipment.
Install check valve (2) on nipple (3). Ensure directional arrow on check valve (2) points toward
2.
hydraulic reservoir (4).
Install union assembly (5) and hose assembly (1) on check valve (2).
3.
Position new O-ring (10) on threaded end of adapter assembly (8).
4.
Install check valve (7) and adapter assembly (8) on elbow (9).
5.
Connect hose assembly (6) to check valve (7).
6.
3-1156