Table 2-3. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 2. Test flasher harness continuity.
flasher unit. Connect negative lead to terminal H of control unit cable, and observe
multimeter for continuity.
Step 2. Connect multimeter negative lead to terminal F of control unit socket and positive lead
to terminal B of flasher unit. Observe multimeter for continuity.
Step 3. Connect multimeter positive lead to terminal C of flasher unit connector. Connect
negative lead to ground, and observe multimeter for continuity.
b. If all leads have continuity and turn signals still do not work, replace flasher
c. If turn signals still do not work, perform malfunction 25.
END OF TESTING!