TM 9-2320-272-24-1
Table 2-3. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Place battery switch and light switch to OFF position.
Step 9.
Step 10.
Disconnect lead 16 from high-beam selector switch,
Step 11.
Place battery switch to ON position and light switch to SERVICE DRIVE position.
Step 12.
With negative lead of multimeter connected to ground, connect positive lead of
multimeter to lead 16 (not switch terminals), Multimeter should indicate battery
voltage.
a, If battery voltage is indicated, replace high-beam selector switch (para. 3-112).
b. If battery voltage is not indicated, perform malfunction 16, test 4.
CAUTION
Lead 15 or wire 15 is hot whenever the batteries are connected.
CIRCUIT
WIRE NO.
LIGHT SWITCH TO
16
SELECT OR SWITCH
HIGH BEAM
17
LOW BEAM
18
END OF TESTING!