TM 9-2320-272-24-1
1-22. ELECTRICAL SYSTEMS OPERATION (Contd)
The electrical portion of the heating system is identical for all models covered in this manual and
consists of the following major components and circuitry:
Key Item and Function
7 PROTECTIVE CONTROL BOX - Provides 24-volt power to circuit breaker through circuits 5 and
5A and to heater switch through circuits 27 and 5C.
8 CIRCUIT BREAKER - Provides overload protection for 24-volt circuits 5, 5A, 27, and 5C leading to
the heater switch.
9 BATTERY SWITCH - Provides 12-volt battery power from circuit 569 through 569A to the heater.
10 CIRCUIT BREAKER - Provides overload protection for 12-volt circuit 569A leading to heater
switch.
11 HEATER SWITCH - Controls low and high blower motor speed and has two sources of power: 12-
volt power is supplied through circuit 569A from battery switch and is used to provide low speed;
24-volt power is supplied through circuit 5C from protective control box and is used to provide high
speed.
12 HEATER BLOWER MOTOR -A direct current motor controlled by heater switch through
circuit 400.
1-51