TM 9-2320-260-34-2
17-24. PERSONNEL HEATER HEAT EXCHANGER MAINTENANCE (Contd)
c. Installation
Spread heater housing (5) and install heat exchanger (3) in heater housing (5) with three new screw-
assembled lockwashers (4). Ensure exhaust tube (2) and flame detector switch adapter (1) extend
through holes of heater housing (5) properly.
FOLLOW-ON TASKS:
q Install personnel heater flame detector switch
17-65