TM 9-2320-260-34-2
15-32. EXTERIOR SIDE PANEL MAINTENANCE (Contd)
1. For general cleaning instructions, refer to para. 2-8.
2. For general inspection instructions, refer to para. 2-9.
3. Inspect five retainers (12), retainers (13), (5), and (6) for cracks and bends. Replace
retainer(s) (12), (13), (5), or (6) if cracked or broken.
4. Inspect bracket (3), retainers (9) and (10), and channel (11) for rust corrosion and breaks. Replace
bracket (3), retainer(s) (9) or (10), or channel (11) if rusted, corroded, or broken.
5. Inspect molding (4), two ladder hangers (8), and side panel frame (2) for cracks, breaks, and
warpage. Replace molding (4), ladder hanger(s) (8) or side panel frame (2) if cracked, broken,
or warped.
6. Inspect skins (1) and ( 14) and lower skin (7) for tears and punctures. Replace skin(s) (1) or (14)
or lower skin (7) if torn or punctured.
NOTE
Left and right exterior side panels are assembled the same. This
procedure covers the right exterior side panel.
Perform steps 1 through 3 if skin was removed.
Assistant will help with steps 1 through 3.
1.
Install two ladder hangers (8) on side panel frame (2) with eight screws (23).
Install lower skin (7) on side panel frame (2) with twenty-four new rivets (24).
2.
Install skins (1) and (14) on side panel frame (2) with two hundred forty-eight new rivets (22).
3.
NOTE
Apply sealing compound to exterior joints for installation.
Apply adhesive to rubber and metal surfaces for installation.
4.
Install molding (19) on doorway of side panel frame (2) with nine screws ( 18).
5.
Install new channel seal (20) on doorway of side panel frame (2).
Install two new seals (16) and retainers (5) on side panel frame (2) with eighty-two screws (15),
6.
nuts (17), and four screws (21).
7.
Install new seal (26) and bracket (25) on skins (1) and (14) and side panel frame (2) with
one hundred eighty-nine new rivets (27).
15-110