TM 9-2320-260-34-1
5-9. INJECTOR LEAKAGE TEST (Contd)
3. place retraction lever (3 in "A" position, and install load cell (2) on leakage tester (1).
4. Turn knob (4) until load cell (2) reads 200 psi (1379 kpa).
5. Remove load cell (2) from leakage tester (1).
5-20