3-84. TOP STOP INJECTOR PLUNGER TRAVEL ADJUSTMENT (Contd)
14. Push "i/m" (inch/millimeter) selector button (2) on digimatic indicator (1) until "in" is displayed.
NOTE
To use U.S. customary values, the display on the digimatic
indicator must display and `in".
To use metric values, the display on the digimatic indicator must
and "mm".
display
15. Push direction selector button (3) on digimatic indicator (1)
is displayed.
16. Press PSET button (4) sand enter the top stop setting fixture preset value using numbered key (6) on
digimatic presetter (5). Ensure a "P' is indicated on digimatic indicator.
NOTE
Preset values must be indicated on digimatic indicator before pre-
ceding with plunger travel setting or an incorrect reading will be
taken for the plunger travel.
17. Press LOAD button (7) and wait 5 seconds or until the digimatic indicator (1) displays preset .
readings.