TM 9-2320-260-20
Table 2-4. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 1. Set multimeter to RX1 scale.
Step 2. Touch positive lead of multimeter to connector for lead 575.
Step 3. Touch negative lead of multimeter to connector for lead 570. There should be 0.2 ohms
present.
Step 4. Touch positive lead of multimeter to connector for lead 575.
Step 5. Touch negative lead of multimeter to connector for lead 576. There should be 0.2 ohms
present.
Step 6. Touch positive lead of multimeter to connector for lead 575.
Step 7. Touch negative lead of multimeter to connector for lead 571. Continuity should be
present.
a. If continuity is present, go to test 5.
b. Repair or replace lead 571 if continuity is not present (para. 4-52).
2-171