ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
163. ALL ELECTRICAL
2. Open PDM2.
GAGES DO NOT
OPERATE -
Continued
3. If circuit breaker CB76 is
tripped, push button to reset.
4. Position master power switch
to on (WP 0004 00).
5. Check circuit breaker CB76 to
see if it is tripped again.
6. Position master power switch
to off (WP 0004 00).
7. If circuit breaker CB76 is
tripped again, contact
supervisor.
8. If circuit breaker is not tripped,
go to test 5 of this malfunction
0080 00-132