ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
85. PERSONNEL
1. Check circuit breaker
1. Remove PDP cover (WP 0113
HEATER FAN DOES
CB23 in PCB to see if
00).
NOT OPERATE
it is tripped.
2. If circuit breaker is tripped,
push in to reset.
3. Position master power switch
to on (WP 0004 00).
4. Check circuit breaker to see if
it is tripped again. If circuit
breaker is tripped or trips
again, notify Field
Maintenance.
5. Position master power switch
to off (WP 0004 00).
6. Install PDP cover (WP 0113
00).
0080 00-87