Table 3. Electrical System Troubleshooting Procedures.- Continued - TM-9-2320-392-10-20106
Table 3. Electrical System Troubleshooting Procedures.- Continued - TM-9-2320-392-10-20108

TM-9-2320-392-10-2 M1083A1 Series 5-Ton 6x6 Medium Tactical Vehicles (MTV) Manual
Page Navigation
  58    59    60    61    62  63  64    65    66    67    68  
TM 9-2320-392-10-2
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0080 00
ELECTRICAL SYSTEM Continued
Table 3. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. FUEL GAGE DOES
2. Has Preventative
1. If PMCS Before checks have
NOT OPERATE OR
Maintenance Checks
not been performed, perform
IS INACCURATE -
and Services (PMCS)
PMCS Before checks (WP 0103
Continued
Before checks been
00).
performed?
2. If PMCS Before checks have
been performed, go to test 3
of this malfunction.
3. Check to see if any
1. Position master power switch
instrument panel
to on (WP 0004 00).
gages operate.
2. If no instrument panel gages
operate, perform Malfunction
163 (All Electrical Gages Do
Not Operate).
3. If fuel gage does not operate
or is inaccurate, notify Field
Maintenance.
4. Position master power switch
to off (WP 0004 00).
8. WATER TEMP
1. Check to see if any
1. Position master power switch
GAGE DOES NOT
instrument panel
to on (WP 0004 00).
OPERATE OR IS
gages operate.
INACCURATE
2. If no instrument panel gages
operate, perform Malfunction
163 (All Electrical Gages Do
Not Operate).
3. If WATER TEMP gage does not
operate or is inaccurate, go to
test 2 of this malfunction.
4. Position master power switch
to off (WP 0004 00).
0080 00-23