TM 9-2320-366-20-4
7-96. M1084/M1086 REMOTE CONTROL CABLE REPLACEMENT (CONT)
(2) Install quick disconnect terminal (6) on ground strip (7)
position 12.
(3) Install ten terminal lugs (8) on terminal block (9)
positions 17 through 26 with ten screws (10).
(4) Install two terminal lugs (11) on terminal block (12)
positions 9 and 14 with two screws (10).
(5) Apply varnish to quick disconnect terminal (6) and
terminal lugs (8 and 11).
(6) Close cover (13) on junction box (2).
(7) Tighten four screws (14) on junction box (2).
(8) Route remote control cable (1) to mounting bracket (15).
(9) Install remote control cable (1) in mounting bracket (15)
with lockwasher (16) and nut (17).
(10) Install cap (18) on connector (19).
c. Follow-On Maintenance.
(1) Connect batteries (para 7-57).
(2) Operate MHC and check remote control operation (TM
9-2320-366-10-1).
End of Task.
7-476